These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: An improved coating for the isolation and quantitation of interferon-gamma in spiked plasma using surface plasmon resonance (SPR).
    Author: Stigter EC, de Jong GJ, van Bennekom WP.
    Journal: Biosens Bioelectron; 2005 Sep 15; 21(3):474-82. PubMed ID: 16076437.
    Abstract:
    A study was initiated to investigate the use of surface plasmon resonance (SPR) for the detection in plasma of a high pI model protein, recombinant human interferon-gamma (IFN-gamma). Initially a number of self-assembled monolayers (SAMs) and hydrogel-derivatised SAM-coatings were characterised for the adsorptive and desorptive properties of plasma components. Next a monoclonal anti-IFN-gamma antibody, MD-2, was covalently attached to dextran-modified mercaptoundecanoic acid surfaces that performed best. On coatings consisting of carboxyl-modified dextran (CMD) a difference in interaction behaviour was observed when IFN-gamma was injected in either buffer or diluted plasma. During the injection of IFN-gamma in buffer, an acceleration of the interaction process was observed and the signal continued to increase after the injection plug had passed. Upon injection of diluted plasma spiked with IFN-gamma, the response increased without acceleration of the binding process. After the injection was finished, some of the bound material desorbed as expected, resulting in a signal decrease. On non-charged dextrans, the interaction between the antibody-modified surface and IFN-gamma in either plasma or buffer was similar. During sample injection the response increased with a binding rate depending on the concentration of IFN-gamma present in solution. When the injection was finished, some of the bound material was washed away from the surface and only a minor contribution of non-specific adsorbed plasma components was noticeable. From the coatings tested, the non-modified dextran-coated SPR sensor disks prove to be best suited for the detection of IFN-gamma in complex matrices like plasma. The interaction of IFN-gamma in both diluted plasma and buffer is comparable and concentrations of IFN-gamma of 250 ng ml-1 and higher can be detected in both buffer and 100x-diluted plasma. The non-specific adsorption of plasma components is low, whereas the specific IFN-gamma response is relatively high.
    [Abstract] [Full Text] [Related] [New Search]