These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Two-dimensional micro-bubble actuator array to enhance the efficiency of molecular beacon based DNA micro-biosensors.
    Author: Deng P, Lee YK, Cheng P.
    Journal: Biosens Bioelectron; 2006 Feb 15; 21(8):1443-50. PubMed ID: 16099153.
    Abstract:
    Two-dimensional micro-bubble actuator arrays were developed and studied in detail to enhance the hybridization kinetics of a DNA micro-biosensor. The hybridization between a molecular beacon, a kind of oligonucleotide probe, and its complement was investigated in a millimeter-sized PDMS based reaction chamber, where various 2D micro-heater arrays were distributed on the bottom for micro-bubble generation. The hybridization assay without the micro-bubble actuation revealed that the fluorescence increased fast at the beginning and slowed down after that. However, a uniform fluorescence increase was observed when periodic micro-bubble agitation was introduced in the static hybridization solution. A comparison of hybridization assays with and without micro-bubble agitation revealed that the hybridization time could be effectively shortened by 33% with 10 cycles of micro-bubble agitation from a 2 x 1 bubble actuator array, and by 43% with 10 cycles of micro-bubble agitation from a 2 x 2 bubble actuator array.
    [Abstract] [Full Text] [Related] [New Search]