These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: [Determination of ligustrazine in human plasma by high performance liquid chromatography with solid-phase extraction].
    Author: Weng W, Shen T, Xu H, Zhang J, Huang J, Huang Z, Cai J.
    Journal: Se Pu; 2005 May; 23(3):276-8. PubMed ID: 16124574.
    Abstract:
    A high performance liquid chromatographic method was developed for the determination of ligustrazine in human plasma. The chromatographic separation was performed on a Luna C18 column (150 mm x 4.6 mm i.d., 5 microm) at column temperature of 40 degrees C. The mobile phase, a mixture of methanol-acetonitrile-acetate buffer of pH 5.0 (50:8:42, v/v), was delivered at a flow rate of 1.0 mL/min. The detection wavelength was 280 nm. Plasma samples were prepared with a C8 solid-phase extraction column. Linearity was confirmed in the mass concentration range of 25-5000 microg/L with the correlation coefficient of 0.9999. The extraction recovery of ligustrazine ranged from 96.72% to 100.90%. The relative standard deviations (RSDs) of intra- and inter-day assay at the mass concentrations of 50, 500 and 3000 microg/L were less than 8.64% and the accuracies were between 99.59%-103.26%. The limit of detection (LOD) was 10 microg/L. The results of this method validation satisfactorily meet the acceptance criteria of bioanalysis and the method is applicable to the pharmacokinetic studies of ligustrazine in human beings.
    [Abstract] [Full Text] [Related] [New Search]