These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Novolizer: how does it fit into inhalation therapy?
    Author: Magnussen H.
    Journal: Curr Med Res Opin; 2005; 21 Suppl 4():S39-46; discussion S47. PubMed ID: 16138944.
    Abstract:
    Inhalation therapy is the preferred route of administration of anti-asthmatic drugs to the lungs. However, the vast majority of patients cannot use their inhalers correctly, particularly pressurised metered dose inhalers (pMDIs). The actual proportion of patients who do not use their inhalers correctly may even be under-estimated as GPs tend to over-estimate correct inhalation technique. Dry powder inhalers (DPIs) have many advantages over pMDIs. Unlike pMDIs, they are environmentally-friendly, contain no propellant gases and, more importantly, they are breath-activated, so that the patient does not need to coordinate actuation of the inhaler with inspiration. Three key parameters for correct inhaler use should be considered when evaluating existing or future DPI devices and especially when choosing the appropriate device for the patient: (1) usability, (2) particle size distribution of the emitted drug and (3) intrinsic airflow resistance of the device. The Novolizer is a breath-activated, multidose, refillable DPI. It is easy to use correctly, has multiple feedback and control mechanisms which guide the patient through the correct inhalation manoeuvre. In addition, the Novolizer has an intelligent dose counter, which resets only after a correct inhalation and may help to monitor patient compliance. The Novolizer has a comparable or better lung deposition than the Turbuhaler at similar or higher peak inspiratory flow (PIF) rates. A flow trigger valve system ensures a clinically effective fine particle fraction (FPF) and sufficient drug delivery, which is important for a good lung deposition. The FPF produced through the Novolizer is also relatively independent of flow rate and the device shows better reproducibility of metering and delivery performance compared to the Turbuhaler. The low-to-medium airflow resistance means that the Novolizer is easy for patients to use correctly. Even children, patients with severe asthma and patients with moderate-to-severe chronic obstructive pulmonary disease (COPD) have no problems to generate the trigger inspiratory flow rate required to activate the Novolizer. The Novolizer uses an advanced DPI technology and may improve patient compliance.
    [Abstract] [Full Text] [Related] [New Search]