These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: [An obstruction of a valve prosthesis implanted in the tricuspid position].
    Author: Martí V, Augé JM, Tomás L, García J, Carreras F, Padró JM.
    Journal: Rev Clin Esp; 1992 May; 190(8):413-5. PubMed ID: 1620944.
    Abstract:
    Dysfunction of a prosthesis implanted in tricuspid position is a severe complication that may develop with minimal symptoms. A patient who presented clinical manifestations of heart failure for two weeks due to obstruction of a mechanical prosthesis in tricuspid position is described. Fibrinolytic treatment was given unsuccessfully, therefore prosthetic replacement was performed. In the removed prosthesis, a fibrotic pannus which developed in the strut and disc was seen. We review the clinical manifestations, the diagnosis and treatment of the dysfunction of a prosthesis implanted in tricuspid position.
    [Abstract] [Full Text] [Related] [New Search]