Search MEDLINE/PubMed
Title: [An obstruction of a valve prosthesis implanted in the tricuspid position]. Author: Martí V, Augé JM, Tomás L, García J, Carreras F, Padró JM. Journal: Rev Clin Esp; 1992 May; 190(8):413-5. PubMed ID: 1620944. Abstract: Dysfunction of a prosthesis implanted in tricuspid position is a severe complication that may develop with minimal symptoms. A patient who presented clinical manifestations of heart failure for two weeks due to obstruction of a mechanical prosthesis in tricuspid position is described. Fibrinolytic treatment was given unsuccessfully, therefore prosthetic replacement was performed. In the removed prosthesis, a fibrotic pannus which developed in the strut and disc was seen. We review the clinical manifestations, the diagnosis and treatment of the dysfunction of a prosthesis implanted in tricuspid position.[Abstract] [Full Text] [Related] [New Search]