These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Intensity of quartz-tungsten-halogen light polymerization units used in dental offices in Brazil. Author: Santos GC, Santos MJ, El-Mowafy O, El-Badrawy W. Journal: Int J Prosthodont; 2005; 18(5):434-5. PubMed ID: 16220811. Abstract: PURPOSE: To determine the intensity of quartz-tungsten-halogen light polymerization units in dental offices in El Salvador, Brazil. MATERIALS AND METHODS: A team of researchers visited 100 offices in 2003. The team measured light intensity with a radiometer. The age and make of the units and the availability of light meters were recorded. RESULTS: One hundred twenty quartz-tungsten-halogen units were tested. Intensity ranged from 10 to 1,000 mW/cm2, with mean of 255.8 mW/cm2. Almost half (48%) of the units had values equal to or less than 200 mW/cm2. Their age ranged from 1 to 21 years. None of the offices had light meters. CONCLUSIONS: Clinicians should periodically monitor light intensity and carry out maintenance on their light polymerization units.[Abstract] [Full Text] [Related] [New Search]