These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: A novel dual-impedance-analysis EQCM system--investigation of bovine serum albumin adsorption on gold and platinum electrode surfaces. Author: Xie Q, Xiang C, Yuan Y, Zhang Y, Nie L, Yao S. Journal: J Colloid Interface Sci; 2003 Jun 01; 262(1):107-15. PubMed ID: 16256587. Abstract: Both quartz crystal micro-balance (QCM) impedance and electrochemical impedance spectroscopy (EIS) methods are widely used in interface studies. This paper presents details about a new strategy for simultaneous, mutual-interference-free and accurate measurements of QCM impedance and EI, through connecting a suitable capacitance in series with the piezoelectric quartz crystal (PQC) between QCM impedance and EIS measurement instruments. Combined and individual measurements of QCM impedance and EIS during silver deposition gave results comparable with each other, demonstrating the reliability of the proposed method. Bovine serum albumin (BSA) adsorption on gold and platinum electrodes in Britton-Robinson (B-R) buffers was investigated, and the Fe(CN)6(3-)/Fe(CN)6(4-) couple was used as an electrochemical probe to characterize BSA adsorption. While the reversibility of Fe(CN)6(3-)/Fe(CN)6(4-) couple on bare Au and Pt electrodes changed very slightly with decreasing solution pH from pH approximately 7 to pH approximately 2, the standard rate constant (ks) of this couple increased abruptly with solution pH below pH approximately 4.5 at a BSA-modified Au electrode, but decreased with solution pH at a BSA-modified Pt electrode. By analyzing the QCM impedance data with a modified BVD equivalent circuit and the EI data with a modified Randle's equivalent circuit, inflexion changes at pH approximately 4.5 were all found at pH-dependent responses of the resonant frequency, the double-layer capacitance, the capacitance of the adsorbed BSA layer, the peak-absorbance values of BSA solutions at 277.5 and 224.5 nm, and so on. It was also found that a BSA adsorption layer can effectively inhibit gold corrosion during ferrocyanide oxidation in a ferrocyanide-containing BR solution. Some preliminary explanations of these findings have been given. The proposed method is highly recommended for wider applications in surface science.[Abstract] [Full Text] [Related] [New Search]