Title: Vascular response to sirolimus-eluting stents delivered with a nonaggressive implantation technique: comparison of intravascular ultrasound results from the multicenter, randomized E-SIRIUS, and SIRIUS trials. Author: Hoffmann R, Guagliumi G, Musumeci G, Reimers B, Petronio AS, Disco C, Amoroso G, Moses JW, Fitzgerald PJ, Schofer J, Leon MB, Breithardt G. Journal: Catheter Cardiovasc Interv; 2005 Dec; 66(4):499-506. PubMed ID: 16273564. Abstract: BACKGROUND: The effectiveness of SES to reduce the risk of restenosis was initially demonstrated in short lesions using stent implantation with routine pre-dilatation and post-dilatation. This intravascular ultrasound (IVUS) substudy of the E-SIRIUS trial sought to evaluate local arterial responses to sirolimus-eluting stents (SES) delivered with a stent implantation technique allowing direct stenting and only selectively applying high-pressure post-dilatation. METHODS AND RESULTS: IVUS was performed immediately after intervention and at 8-month follow-up in 51 patients randomised to either bare-metal stents (BMS; Bx-Velocitytrade mark; N=20) or SES (Cyphertrade mark N=31). Direct stenting was allowed (24%) and post-dilation was performed only selectively (32%). Lumen dimensions, intimal hyperplasia and vessel remodeling were compared between SES and BMS. Subsequently, results of SES in the E-SIRIUS IVUS substudy (N=31) were compared to those of SES in the IVUS substudy of the SIRIUS trial (N=137). SES in SIRIUS IVUS substudy were delivered with 100% pre-dilatation and 77% post-dilatation. Baseline stent and reference segment measurements were similar between BMS and SES in E-SIRIUS IVUS patients. Using SES there was a 96% reduction in intimal hyperplasia volume within the stented segment (1.8+/-4.9 vs 50.6+/-39.7 mm3, P<0.001) and a significantly larger minimal lumen cross sectional area at 8-month follow-up (4.5+/-1.1 vs 2.3+/-0.9 mm2, P<0.001). No vessel remodeling was observed with the use of SES. The applied stent implantation technique resulted in a minimal stent/reference vessel area ratio of 0.75+/-0.17 in E-SIRIUS SES as compared to 0.84+/-0.23 in SIRIUS SES (P=0.046). Mean intimal hyperplasia cross-sectional area at follow-up was 0.1+/-0.2 mm2 in the SES group of E-SIRIUS and 0.5+/-0.8 mm2 in the SES group of SIRIUS (P=0.003). CONCLUSIONS: An implantation technique of SES which includes direct stenting and minimizes the use of high-pressure post-dilatation results in less optimal stent expansion. However, follow-up results compare very favourable to those of BMS and are characterised by even less intimal hyperplasia than after a more forceful implantation of SES.[Abstract] [Full Text] [Related] [New Search]