These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: C-reactive protein in patients on chronic hemodialysis with different techniques and different membranes.
    Author: Panichi V, Rizza GM, Taccola D, Paoletti S, Mantuano E, Migliori M, Frangioni S, Filippi C, Carpi A.
    Journal: Biomed Pharmacother; 2006 Jan; 60(1):14-7. PubMed ID: 16330177.
    Abstract:
    In hemodialysis patients, C-reactive protein (CRP), an acute-phase reactant, is a sensitive and independent marker of malnutrition, anemia, and cardiovascular mortality. The aim of the present study was to evaluate CRP levels in plasma samples from long-term hemodialysis patients on different extracorporeal modalities and dialyzed with different membranes, at baseline and after 6 months. Two hundred and forty-seven patients were recruited in eight hospital-based centers. All patients had been on their dialytic modality for at least 3 months and were prospectively followed in their initial dialytic modality for 6 months. Patients were treated with conventional bicarbonate dialysis (N = 127) or hemodiafiltration (N = 120). Patients treated with conventional bicarbonate dialysis were dialyzed with different membranes: Cuprophane (N = 51), low-flux cellulose modified membrane (N = 37) and synthetic membranes (N = 39). Hemodiafiltration was performed in post-dilution mode with polysulfone (N = 66) and polyacrylonitrile (N = 54) membranes. Analysis of baseline CRP values in the clinically stable patients showed that an unexpectedly high proportion (47%) of the patients had CRP values higher than 5 mg/l (upper limit in normal subjects). The mean +/- S.D. CRP values were significantly higher (P < 0.05) in hemodiafiltration with infusion volumes < 10 l per session (14.6+/-3.1 mg/l) than in standard hemodialysis (5.1 +/- 2.1 mg/l) and hemodiafiltration with infusion volumes > 20 l per session (4.9 +/- 2.1 mg/l). These values did not significantly change after 6 months of follow-up. Concerning the membranes, the highest levels of CRP were observed in patients dialyzed with Cuprophane with a significant increase from 15.1 +/- 3.6 to 21.2 +/- 3.1 mg/l after 6 months (P < 0.05); a significant reduction of CRP levels was observed in patients dialyzed with polysulfone in the same follow-up period (from 13.5 +/- 2.9 to 8.1 +/- 2.4 mg/l; P < 0.05). The CRP increase following low volume HDF can be related to back-filtration of bacterial derived contaminants.; moreover, an important effect on CRP of the hemodialysis membrane is observed and new synthetic membranes can be used to decrease these levels.
    [Abstract] [Full Text] [Related] [New Search]