These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Catheter ablation of accessory atrioventricular pathways in 114 symptomatic patients with Wolff-Parkinson-White syndrome--a comparative study of direct-current and radiofrequency ablation. Author: Chen SA, Tsang WP, Hsia CP, Wang DC, Chiang CE, Yeh HI, Chen JW, Ting CT, Kong CW, Wang SP. Journal: Am Heart J; 1992 Aug; 124(2):356-65. PubMed ID: 1636579. Abstract: To evaluate and compare the safety and efficacy of catheter-mediated direct-current and radiofrequency ablation in patients with Wolff-Parkinson-White syndrome, 114 patients with accessory pathway-mediated tachyarrhythmias underwent catheter ablation. Electrophysiologic parameters were similar in patients undergoing direct-current (group 1, 52 patients with 53 accessory pathways) and radiofrequency (group 2, 62 patients with 75 accessory pathways) ablation. Immediately after ablation, 50 of 53 accessory pathways (94%) were ablated successfully with direct current, but 2 of the 50 accessory pathways had early return of conduction and required a second ablation; 72 of 75 accessory pathways (96%) were ablated successfully with radiofrequency current. In the three accessory pathways in which radiofrequency ablation was unsuccessful, a later direct-current ablation was successful. During follow-up (group 1, 14 to 27 months; group 2, 8 to 13 months), none of the patients with successful ablation had a recurrence of tachycardia. Complications in direct-current ablation included transient hypotension (two patients), accidental atrioventricular block (one patient), and pulmonary air trapping (two patients); complications in radiofrequency ablation included cardiac tamponade (one patient) and suspicious aortic dissection (one patient). Myocardial injury and proarrhythmic effects were more severe in direct-current ablation. The length of the procedure and the radiation exposure time were significantly shorter in direct-current (3.5 +/- 0.2 hours, 30 +/- 4 minutes) than in radiofrequency (4.1 +/- 0.4 hours, 46 +/- 9 minutes) ablation. Findings in this study confirm the impression that radiofrequency ablation is associated with fewer complications than direct-current ablation and radiofrequency ablation with a large-tipped electrode catheter is an effective and relatively safe nonsurgical method for treatment of Wolff-Parkinson-White syndrome.[Abstract] [Full Text] [Related] [New Search]