These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: [Pharmacokinetics of (-)-clausenamide and its major metabolite 6-hydroxyl-clausenamide in beagle dogs by HPLC/MS]. Author: Song M, Qian W, Hang TJ, Zhang ZX. Journal: Yao Xue Xue Bao; 2005 Oct; 40(10):940-4. PubMed ID: 16408814. Abstract: UNLABELLED: To establish a sensitive and accurate method to study the pharmacokinetics of (-)-clausenamide [(-)-clau] and its major metabolite 6-hydroxyl-clausenamide (6-OH-clau) in the plasma of the Beagle dog. METHODS: (-)-Clau was orally administered to six Beagle dogs at the dose of 30 mg x kg(-1), venous blood from front leg was sampled and plasma was separated for analysis. After extraction with ethyl acetate, the plasma samples were analyzed by HPLC/MS and the mobile phase was a mixture of methanol-water-acetic acid (60: 40: 0. 8) at the flow rate of 1.0 mL x min(-1). The API-ES positive ion SIM detection was carried out for the detection of both (-)-clau ([M + H] (+), m/z 298 ) and 6-OH-clau ([M + H - H2 O](+), m/z 296) with glipzide (glip) ([M + H](+), m/z 446) as internal standard. The pharmacokinetic parameters were calculated by 3P97 software. RESULTS: There was good linear relationship ( r > 0. 999) between the SIM responses and the concentrations for (-)-clau and 6-OH-clau at the range from 1.0 to 200 ng x mL(-1) and 0.2 to 40.0 ng x mL(-1), respectively. The absolute recovery was greater than 85%. The plasma concentration-time curves of (-)-clau and 6-OH-clau were both best fitted to a two-compartment model. The C(max) of (-)-clau and 6-OH-clau were (21 +/- 10) ng x mL(-1) and (3.9 +/- 2.2) ng x mL(-1), T(max) were (0.8 +/- 0.5) h and (1.3 +/- 0.5) h, T 1/2 alpha were (0.9 +/- 0.6) hand (1.4 +/- 0.6) h, T 1/2 beta were (19 +/- 23) hand (13 +/- 12) h, AUC(0-24 h) were (69 +/- 14) h x ng x mL(-1) and (12 +/- 7) h x ng x mL(-1) respectively. CONCLUSION: The established HPLC/MS method was sensitive and specific for the determination of (-)-clau. It was shown that the absorption and first phase elimination of (-)-clau were very quick in Beagle dogs, but the terminal elimination was very slow. The plasma concentration profile of its major metabolite 6-OH-clau was similar to (-)-clau and the AUC was relatively small in comparison with (-)-clau.[Abstract] [Full Text] [Related] [New Search]