These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Effect of lacrimal punctal occlusion on tear production and tear fluorescein dilution in normal dogs. Author: Gelatt KN, MacKay EO, Widenhouse C, Widenhouse TS, Stopek JB. Journal: Vet Ophthalmol; 2006; 9(1):23-7. PubMed ID: 16409241. Abstract: OBJECTIVE: To evaluate effects of lacrimal punctal plugs positioned in either the upper, lower, or combination of upper and lower lacrimal canaliculi on plug retention and tolerance; tear production, as measured by the Schirmer tear test; and the dilution of fluorescein within the tear film in normal dogs. MATERIAL AND METHODS: Lacrimal punctal plugs were positioned in the lower, upper, or combination of lower and upper plugs in six laboratory-quality Beagles under topical anesthesia. Retention of plugs was evaluated daily from 8 to 23 days by visual inspection and slit-lamp biomicroscopy. Schirmer tear tests (STT 1 without topical anesthesia) were performed at 48-h intervals. Dilution of fluorescein was determined at 5- and 45-min post-fluorescein instillations once weekly. RESULTS: Lacrimal punctal plugs of 0.4 and 0.6 mm in diameter were retained for 14 (lower plugs: 100%) and 23 days (75%), and for the upper plugs at 8 days less often (75%), and were infrequently locally nonirritating. Combination of lower and upper plugs seemed to adversely affect retention of either plug. When loss of the plugs occurred, a next larger size plug was necessary suggesting some stretching of the lacrimal canaliculi occurred. Pre- and postplug placement STT results indicated no change with lower and combination lacrimal punctal plugs, but decreased levels following upper lacrimal punctal plugs. Tear fluorescein levels at 5 and 45 min in control eye (no punctum plugs) were 3.39% and 0.14%, respectively. With lower, upper, and the combination of lower and upper lacrimal puncta plugs, tear fluorescein levels at 45 min were higher than the controls (lower: 0.76%; upper: 0.45%, and combination 0.56%). CONCLUSION: Lacrimal punctal silicone plugs are retained for 8-23 days in the lower, upper, and combined lower and upper canaliculi at high rates. Effects on STT levels appear limited. Fluorescein within the tear film persists longer with all different positioned lacrimal punctum plugs than in the control eyes.[Abstract] [Full Text] [Related] [New Search]