These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: 3.0- Versus 1.5-T MR cholangiography: a pilot study.
    Author: Merkle EM, Haugan PA, Thomas J, Jaffe TA, Gullotto C.
    Journal: AJR Am J Roentgenol; 2006 Feb; 186(2):516-21. PubMed ID: 16423962.
    Abstract:
    OBJECTIVE: The purpose of our study was to evaluate quantitative and qualitative image quality of MR cholangiography at a field strength of 3.0 T compared with the standard field strength of 1.5 T. MATERIALS AND METHODS: A standardized MR cholangiography sequence protocol was used for 15 healthy male volunteers (mean age +/- SD, 32.4 +/- 4.3 years) who underwent both 1.5- and 3.0-T MRI within 2 hr in an alternating fashion. Dedicated circular polarized torso coils (1.5 and 3.0 T) were used. The sequence protocol included breath-hold single-slice rapid acquisition with relaxation enhancement (slice thickness, 50 mm; orientation, coronal and +/- 20 degrees oblique coronal); breath-hold multislice HASTE (slice thickness, 3 mm; coronal only); and a non-breath-hold, respiratory-triggered 3D turbo spin-echo (TSE) T2-weighted sequence (slice thickness, 1 mm; 60 slices per slab; coronal only). Maximum intensity projections were generated from each multislice data set. Bile duct (common bile duct, right posterior segmental branch, and left hepatic duct) to periductal tissue contrast-to-noise ratios were compared at 1.5 and 3.0 T. Qualitative image analysis was performed by three independent reviewers. Qualitative analysis included delineation of the extra- and intrahepatic biliary anatomy, with specific attention given to the presence (or absence) of cystic or intrahepatic ductal variants, using a 4-point confidence scale. Statistical analysis consisted of the paired Student's t test and the signed rank test. RESULTS: Contrast-to-noise ratios between the bile duct and the periductal tissue were higher at 3.0 T in all three locations (common bile duct, right posterior segmental branch, and left hepatic duct). In each magnet class, the 3D TSE sequence offered the best contrast-to-noise ratio and qualitative analysis. Superiority of the 3D TSE sequence was statistically significant in all analyses. Five of the 15 volunteers had intrahepatic biliary variants that were detected with a higher level of confidence (p < 0.01) on the 3.0-T system than on the 1.5-T system. CONCLUSION: Compared with MR cholangiography at 1.5 T, MR cholangiography at 3.0 T offers improved contrast-to-noise ratio and a higher level of confidence for depicting intrahepatic variants.
    [Abstract] [Full Text] [Related] [New Search]