These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Flow injection chemiluminescent determination of amiodarone in pharmaceutical preparations using photogenerated tris(2,2'-bipyridyl)ruthenium(III).
    Author: Pérez-Ruiz T, Martínez-Lozano C, Martín J, Ruiz E.
    Journal: J Pharm Biomed Anal; 2006 Sep 11; 42(1):143-7. PubMed ID: 16458471.
    Abstract:
    A flow injection configuration was developed and evaluated for the chemiluminescent determination of amiodarone. The method is based on the reaction of the drug with tris(2,2'-bipyridyl)ruthenium(III), which was generated through the on-line photo-oxidation of tris(2,2'-bipyridyl)ruthenium(II) with peroxydisulfate. Under the optimum experimental conditions, a linear calibration graph was obtained over the range 3.0-60.0 microg ml(-1) with a detection limit of 0.28 microg ml(-1). The proposed method allows 120 injections h(-1) with excellent repeatability and precision (R.S.D. less than 0.5% and 2.8%, respectively) and a reagent consumption of only 0.37 micromol (0.27 mg) of Ru(bpy)(3)Cl(2) x 6H(2)O per determination. The method was successfully applied to the determination of amiodarone in commercial pharmaceutical formulations.
    [Abstract] [Full Text] [Related] [New Search]