These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: [Primarily study on a multiplex PCR-based system for the rapid detection of Salmonella spp., Shigella spp. and Escherichia coli O157:H7].
    Author: He C, Fan XJ, Wang DL, Liu LY.
    Journal: Wei Sheng Yan Jiu; 2005 Nov; 34(6):721-3. PubMed ID: 16535845.
    Abstract:
    OBJECTIVE: To establish a multiplex PCR-based system for the simultaneous detection of Salmonella spp., Shigella spp. and Escherichia coli 0157:H7 in 12 hours. METHODS: After 6 h nonselective enrichment in BPW, DNA template were prepared at 100 degrees C for 10 min. Three sets of primers were designed to amplify the gene segments of invA of Salmonella spp, ipaH of Shigella spp, and uidA of E. coli 0157:H7, and the products were analyzed by electrophoresis. At the same time, this system was optimized, and the specificity and sensitivity of this system were evaluated. RESULTS: Three target bacteria were detected in 12 h by using this multiplex PCR-based system. The sensitivity of it was up to 10-30 cfu/ml, and the high specificity was demonstrated by detecting 23 target stains and 15 non-target stains. CONCLUSION: A rapid, specific, and sensitive multiplex PCR-based system for the simultaneous detection of Salmonella spp., Shigella spp. and E. coli 0157:H7 in 12 h has been studied primarily.
    [Abstract] [Full Text] [Related] [New Search]