These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Intensity of transmitted photon spectra as a function of transverse and longitudinal dimensions of soil medium using 137Cs.
    Author: Sidhu GS, Singh T, Mudahar GS, Singh PS.
    Journal: Radiat Prot Dosimetry; 2006; 121(3):317-20. PubMed ID: 16614083.
    Abstract:
    Transmitted photon spectra (pulse-height distribution) of (137)Cs gamma rays are measured through longitudinal and transverse dimensions of the soil medium. The intensity (photon fluence rate) of the multiple-scattered peak, appearing in the lower energy part of the spectrum, has been studied as a function of longitudinal as well as transverse thickness of the soil medium. The intensity of multiple-scatter peak decreases exponentially with the increase in longitudinal thickness of the soil medium, whereas a reverse trend of multiple-scatter peak intensity with transverse thickness occurs as the longitudinal dimension increases. The soil medium as a whole takes part in multiple scattering affecting the intensities of transmitted photons.
    [Abstract] [Full Text] [Related] [New Search]