These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Mechanical complications of central venous catheters.
    Author: Eisen LA, Narasimhan M, Berger JS, Mayo PH, Rosen MJ, Schneider RF.
    Journal: J Intensive Care Med; 2006; 21(1):40-6. PubMed ID: 16698743.
    Abstract:
    We analyzed 385 consecutive central venous catheter (CVC) attempts over a 6-month period. All critically ill patients 18 years of age or older requiring a CVC were included. The rate of mechanical complications not including failure to place was 14%. Complications included failure to place the CVC (n = 86), arterial puncture (n = 18), improper position (n = 14), pneumothorax (n = 5 in 258 subclavian and internal jugular attempts), hematoma (n = 3), hemothorax (n = 1), and asystolic cardiac arrest of unknown etiology (n = 1). Male patients had a significantly higher complication rate than female patients (37% vs 27%, P = .04). The subclavian approach had a higher complication rate than the internal jugular or the femoral approach (39% vs 33% vs. 24%, P = .02). The complication rate increased with the number of percutaneous punctures, with a rate of 54% when more than 2 punctures were required.