These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: HPLC determination of a novel aroylhydrazone iron chelator (o-108) in rabbit plasma and its application to a pilot pharmacokinetic study. Author: Kovaríková P, Klimes J, Sterba M, Popelová O, Gersl V, Ponka P. Journal: J Chromatogr B Analyt Technol Biomed Life Sci; 2006 Jul 11; 838(2):107-12. PubMed ID: 16725389. Abstract: A high performance liquid chromatographic method for the determination of a biocompatible iron chelator, pyridoxal 2-chlorobenzoyl hydrazone (o-108), in rabbit plasma was developed and validated. The separation was achieved on a C18 column with the mobile phase composed of a mixture of 0.01 M phosphate buffer (pH 6) with the addition of EDTA (2 mM), methanol and acetonitrile (42:24:14; v/v/v). The method was validated with respect to selectivity, linearity (0.8-150 microg/mL), intra- and inter-day variability and stability. This method was successfully applied to the analysis of the samples obtained from a pilot pharmacokinetic experiment, in which the chelator was administered intravenously to rabbits.[Abstract] [Full Text] [Related] [New Search]