These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: A new simplified one port laparoscopic technique of peritoneal dialysis catheter placement with intra-abdominal fixation.
    Author: Harissis HV, Katsios CS, Koliousi EL, Ikonomou MG, Siamopoulos KC, Fatouros M, Kappas AM.
    Journal: Am J Surg; 2006 Jul; 192(1):125-9. PubMed ID: 16769289.
    Abstract:
    BACKGROUND: Various laparoscopic techniques have been described for the insertion of peritoneal dialysis catheters. However, most use 3 to 4 ports, thus multiplying the potential risk for abdominal wall complications (hemorrhage, hernia, leaking). METHODS: A Tenckhoff catheter was placed laparoscopically, using just 1 port, in 13 consecutive patients with end-stage renal failure. All catheters were fixed in the abdominal cavity with no additional ports for this purpose. RESULTS: After a follow-up of 76 patient-months, all catheters are working properly. There were no postoperative wall hemorrhages, early leaking, or hernias. There was 1 case of catheter migration and 2 cases of late leaking in 2 patients in total, due to severe constipation. There were no exit site or tunnel infections. One episode of peritonitis was successfully treated with antibiotics. CONCLUSION: The simplicity and the rapidity of the method justifies serious consideration for its use as the standard Tenckhoff catheter placement.
    [Abstract] [Full Text] [Related] [New Search]