These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Metal-framed spectacles and implants and specific absorption rate among adults and children using mobile phones at 900/1800/2100 MHz.
    Author: Joó E, Szász A, Szendrö P.
    Journal: Electromagn Biol Med; 2006; 25(2):103-12. PubMed ID: 16771299.
    Abstract:
    The specific absorption rate (SAR) from mobile telephones at horizontal and vertical positions is investigated in human adult and child heads wearing metal-rim spectacles and having metallic implants. The SAR values calculated by Finite Difference Time Domain (FTDT) method are compared to the actual ANSI/IEEE standards and to the 900/1800/2100 MHz electromagnetic radiation limits according to EU standards. Our calculation shows a maximum of the cellular SAR in the child head, which in the case of metallic implant could be as much as 100% higher than in the adult head. The averaging on 1 and 10 g tissue-masses shows SAR generally under the limit of 519/1999/EC standards. However, in the case of 2100 MHz with vertical position of the phone for adults and of the 900 MHz for children with metallic implants the ANSI/IEEE limits are exceeded.
    [Abstract] [Full Text] [Related] [New Search]