These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Analysis and validation of the phosphorylated metabolites of two anti-human immunodeficiency virus nucleotides (stavudine and didanosine) by pressure-assisted CE-ESI-MS/MS in cell extracts: sensitivity enhancement by the use of perfluorinated acids and alcohols as coaxial sheath-liquid make-up constituents. Author: Bezy V, Chaimbault P, Morin P, Unger SE, Bernard MC, Agrofoglio LA. Journal: Electrophoresis; 2006 Jun; 27(12):2464-76. PubMed ID: 16786481. Abstract: A CE method utilizing triple quadrupole electrospray (ES) MS (MS/MS) detection was developed and validated for the simultaneous measurement of nucleoside 5'-triphosphate and 5'-monophosphate anabolites of the anti-HIV (human immunodeficiency virus) didanosine (ddAMP, ddATP) and stavudine (d4TMP, d4TTP), among a pool of 14 endogenous 5'-mono-, di-, and triphosphate nucleosides. These compounds were spiked and extracted from peripheral blood mononuclear cells (PBMCs) which are the sites of HIV replication and drug action. An acetic acid/ammonia buffer (pH 10, ionic strength of 40 mM) was selected as running electrolyte, and the separation was performed by the simultaneous application of a CE voltage of +30 kV and an overimposed pressure of 28 mbar (0.4 psi). The application of pressure assistance was needed to provide stable ES conditions for successful coupling. The coupling was carried out with a modified sheath-flow interface, with one uninterrupted capillary (80 cmx 50 microm id; 192 microm od) in a dimension that fits into the ESI needle to get a stable ion spray. Some CE-MS parameters such as overimposed pressure, sheath-liquid composition, sheath-liquid and sheath-gas flow rates, ES voltage, and the CE capillary position were optimized in order to obtain an optimal sensitivity. The use of perfluorinated alcohols and acids in the coaxial sheath-liquid make-up (2,2,2-trifluoroethanol + 0.2 mM tridecafluoroheptanoic acid) appeared to provide the best MS sensitivity and improve the stability of spray. The linearity of the CE-MS and CE-MS/MS methods was checked under these conditions. Validation parameters such as accuracy, intraday and interday precision, and LOQs were determined in CE-MS/MS mode. Finally, the quantitation of d4T-TP and ddA-TP was validated in this CE-MS/MS system.[Abstract] [Full Text] [Related] [New Search]