These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Cost-effectiveness of a microvolt T-wave alternans screening strategy for implantable cardioverter-defibrillator placement in the MADIT-II-eligible population. Author: Chan PS, Stein K, Chow T, Fendrick M, Bigger JT, Vijan S. Journal: J Am Coll Cardiol; 2006 Jul 04; 48(1):112-21. PubMed ID: 16814657. Abstract: OBJECTIVES: This study was designed to compare the cost-effectiveness of implantable cardioverter-defibrillator (ICD) placement with and without risk stratification with microvolt T-wave alternans (MTWA) testing in the MADIT-II (Second Multicenter Automatic Defibrillator Implantation Trial) eligible population. BACKGROUND: Implantable cardioverter-defibrillators have been shown to prevent mortality in the MADIT-II population. Microvolt T-wave alternans testing has been shown to be effective in risk stratifying MADIT-II-eligible patients. METHODS: On the basis of published data, cost-effectiveness of three therapeutic strategies in MADIT-II-eligible patients was assessed using a Markov model: 1) ICD placement in all; 2) ICD placement in patients testing MTWA non-negative;, and 3) medical management. Outcomes of expected cost, quality-adjusted life-years (QALYs), and incremental cost-effectiveness were determined for patient lifetime. RESULTS: Under base-case assumptions, providing ICDs only to those who test MTWA non-negative produced a gain of 1.14 QALYs at an incremental cost of 55,700 dollars when compared to medical therapy, resulting in an incremental cost-effectiveness ratio (ICER) of 48,700 dollars/QALY. When compared with a MTWA risk-stratification strategy, placing ICDs in all patients resulted in an ICER of 88,700 dollars/QALY. Most (83%) of the potential benefit was achieved by implanting ICDs in the 67% of patients who tested MTWA non-negative. Results were most sensitive to the effectiveness of MTWA as a risk-stratification tool, MTWA negative screen rate, cost and efficacy of ICD therapy, and patient risk for arrhythmic death. CONCLUSIONS: Risk stratification with MTWA testing in MADIT-II-eligible patients improves the cost-effectiveness of ICDs. Implanting defibrillators in all MADIT-II-eligible patients, however, is not cost-effective, with one-third of patients deriving little additional benefit at great expense.[Abstract] [Full Text] [Related] [New Search]