These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Femoral stress fracture after computer navigated total knee arthroplasty. Author: Ossendorf C, Fuchs B, Koch P. Journal: Knee; 2006 Oct; 13(5):397-9. PubMed ID: 16839767. Abstract: Computer navigation for total knee arthroplasty is increasingly used because it improves the accuracy of femoral and tibial components implantation. However, every new technique is associated with its own complications. Here, we report on a patient who developed a distal femoral stress fracture after two attempts at fixing the navigation tracker.[Abstract] [Full Text] [Related] [New Search]