These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Platelet-dependent thrombography: a method for diagnostic laboratories.
    Author: Dargaud Y, Luddington R, Baglin T.
    Journal: Br J Haematol; 2006 Aug; 134(3):323-5. PubMed ID: 16848775.
    Abstract:
    The thrombin-platelet feedback loop was examined at low concentration tissue factor using calibrated automated thrombography in combination with the elimination of contact factor activation by corn trypsin inhibitor. The results indicated that, when contact factor activation was eliminated, the thrombin-platelet feedback loop was a major determinant of thrombin generating capacity and that platelets had a greater role in regulating the propagation of thrombin generation than its initiation. This method has potential application to the measurement of platelet-dependent thrombin generation in clinical diagnostic laboratories and hence the investigation of patients with apparent hypo- or hypercoagulable phenotypes.
    [Abstract] [Full Text] [Related] [New Search]