These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: The influence of ramp rate on VO2peak and "excess" VO2 during arm crank ergometry.
    Author: Smith PM, Amaral I, Doherty M, Price MJ, Jones AM.
    Journal: Int J Sports Med; 2006 Aug; 27(8):610-6. PubMed ID: 16874587.
    Abstract:
    The principal aim of this study was to examine how different ramp rates influenced the attainment of peak physiological responses during incremental arm crank ergometry (ACE). Additionally, the study examined whether there was any evidence for the development of an "excess" VO (2) during ACE due to upward curvi-linearity in the VO (2)-work rate relationship, and whether this was influenced by the ramp rate. Sixteen physically active, though non-specifically trained, men (mean +/- S age 30 +/- 8 years; height 1.79 +/- 0.07 m; body mass 84.7 +/- 13.2 kg) volunteered to participate. Having completed a familiarisation test, all subjects returned to the laboratory to complete two ramp tests on an electrically-braked ergometer in a counter-balanced order. Both ramp tests started at 60 W with work rate subsequently incremented by either 6 or 12 W . min (-1). Pulmonary gas exchange was measured breath-by-breath throughout the tests. Subjects achieved a greater final work rate during the 12 W . min (-1) test compared to the 6 W . min (-1) test (168 +/- 28 vs. 149 +/- 26 W; p < 0.001). The VO (2peak) (3.06 +/- 0.65 vs. 2.96 +/- 0.48 L . min (-1); p = 0.27), HR (peak) (179 +/- 15 vs. 177 +/- 16 b . min (-1); p = 0.17) and V.E (peak) (112 +/- 22 vs. 105 +/- 16 L . min (-1); p = 0.09) were not different between the tests, but VCO (2peak) (3.54 +/- 0.64 vs. 3.27 +/- 0.46 L . min (-1); p = 0.01) RER (peak) (1.17 +/- 0.07 vs. 1.11 +/- 0.06; p < 0.001), and end-exercise blood (lactate) (11.9 +/- 2.1 vs. 10.8 +/- 2.6 mmol . L (-1); p = 0.005) were all higher in the 12 W . min (-1) test. An "excess" VO (2) was observed in 13 out of 16 tests at 12 W . min (-1) and in 15 out of 16 tests at 6 W . min (-1). Neither the magnitude of the "excess" VO (2) (0.42 +/- 0.41 vs. 0.37 +/- 0.18 L . min (-1); p = 0.66) nor the VO (2) at which the V.O (2)-work rate relationship departed from linearity (2.17 +/- 0.34 vs. 2.18 +/- 0.32 L . min (-1); p = 0.94) were significantly different between the two ramp tests. These data indicate that differences in ramp rate within the range of 6 - 12 W . min (-1) influence the peak values of work rate, VCO (2) and RER, but do not influence peak values of VO (2) or HR during ACE. The development of an "excess" VO (2) appears to be a common feature of ramp exercise in ACE, although the mechanistic basis for this effect is presently unclear.
    [Abstract] [Full Text] [Related] [New Search]