These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Comparison of the retentive characteristics of cobalt-chromium and commercially pure titanium clasps using a novel method.
    Author: Tse ET, Cheng LY, Luk HW, Chu FC, Chai J, Chow TW.
    Journal: Int J Prosthodont; 2006; 19(4):371-2. PubMed ID: 16900820.
    Abstract:
    This study aimed to compare the retentive forces of cast cobalt-chromium (Co-Cr) and commercially pure titanium (cpTi) clasps. A clasp assembly comprising a pair of symmetrical clasps was made to fit the opposite halves of a hardened stainless-steel sphere. This twin clasp was designed to counterbalance the tipping forces when the clasp assembly was drawn from the sphere. A total of 120 clasp assemblies were fabricated in cast Co-Cr and cpTi and placed at undercut depths of 0.25 mm, 0.50 mm, and 0.75 mm (n = 20 for each). For Co-Cr clasps, the retentive forces at these undercuts depths were 2.34 +/- 0.23 N, 4.65 +/- 0.35 N, and 7.56 +/- 0.50 N, respectively. The corresponding retentive forces for cpTi clasps were 1.24 +/- 0.13 N, 2.34 +/- 0.23 N, and 3.70 +/- 0.27 N. The retentive force of cpTi clasps was approximately half that of Co-Cr clasps for the same undercut depth.
    [Abstract] [Full Text] [Related] [New Search]