These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Syndesmosis fixation: a comparison of three and four cortices of screw fixation without hardware removal.
    Author: Moore JA, Shank JR, Morgan SJ, Smith WR.
    Journal: Foot Ankle Int; 2006 Aug; 27(8):567-72. PubMed ID: 16919207.
    Abstract:
    BACKGROUND: Great variability exists in methods of stabilization for syndesmotic disruptions of the ankle. We hypothesized that syndesmotic screw fixation with 3.5-mm fully threaded cortical screws through either three or four cortices would have similar strength and rate of mechanical failure and that retention of screws after fracture healing would not result in adverse clinical symptoms. METHODS: In a prospective, surgeon-randomized study at a Level-one trauma center, 127 patients with syndesmotic disruptions were treated surgically. Seven patients were lost to followup, leaving 120 for review. Syndesmotic disruptions were stabilized with 3.5-mm fully threaded cortical screws placed through three or four cortices. Screws were removed only if symptomatic. Outcome criteria were screw failure, loss of reduction, and need for hardware removal. RESULTS: Fifty-nine patients received fixation through three cortices and 61 patients received fixation through four cortices. Mean follow-up was 150 days. In the group with stabilization through three cortices, hardware failure occurred in five patients (8%) and three had a loss of reduction. In the group with stabilization through four cortices, hardware failure occurred in four patients (7%); all were asymptomatic and did not require screw removal. There was no loss of reduction in that group. Comparing the two groups using binary logistic analysis, there was no difference in loss of reduction (p = 0.871), screw breakage (p = 0.689), or need for hardware removal (p = 0.731). CONCLUSION: The data suggest that either three or four cortices of fixation can be used when stabilizing syndesmotic injuries of the ankle. There was a trend towards higher loss of reduction in the group with tricortical fixation when weightbearing restrictions were not followed. Retention of the syndesmotic screws, even with mechanical failure, does not pose a clinical problem. Weightbearing can be allowed at 6 to 10 weeks without routine removal of screws.
    [Abstract] [Full Text] [Related] [New Search]