These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Determination of echinacoside in rat serum by reversed-phase high-performance liquid chromatography with ultraviolet detection and its application to pharmacokinetics and bioavailability.
    Author: Jia C, Shi H, Wu X, Li Y, Chen J, Tu P.
    Journal: J Chromatogr B Analyt Technol Biomed Life Sci; 2006 Dec 05; 844(2):308-13. PubMed ID: 16931184.
    Abstract:
    A rapid and simple high-performance liquid chromatographic (HPLC) method has been developed and validated for the determination of echinacoside (ECH) in rat serum. After protein precipitation of serum sample with trichloroacetic acid, the supernatant was directly injected and analyzed on a C(18) CapcellACR analytical column (150 mm x 4.6mm I.D. 5 microm) with a mobile phase consisting of acetonitrile-0.5% acetic acid (15.5:84.5, v/v). The UV detector was set at 330 nm. The lower limit of detection and quantification were 9 and 29.2 ng/mL, respectively, and the calibration curves were linear over the concentration range of 29.2-18250 ng/mL. The assay method was successfully applied to the study of the pharmacokinetics and bioavailability of ECH in rat.