These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Flow analysis coupled with PQC/DNA biosensor for assay of E. coli based on detecting DNA products from PCR amplification. Author: Sun H, Zhang Y, Fung Y. Journal: Biosens Bioelectron; 2006 Oct 15; 22(4):506-12. PubMed ID: 16971109. Abstract: A flow-through PQC/DNA biosensor system is developed by combining sequential flow polymerase chain reaction (PCR) products denaturing prior to piezoelectric quartz crystal (PQC) detection via hybridization of ssDNA. The PQC/DNA biosensor is fabricated based on complex formation of neutravidin/biotinylated probe in 0.2M NaCl in TE buffer (10mM Tris, 1mM EDTA, pH 7.5). Results show that the coating fabricated provides a desirable quality with satisfactory performance. Its application for Escherichia coli detection under controlled flow at 0.02 mL/min for denaturing PCR products and 10 mL/min for transferring solution between reactors and delivering samples to detector to reduce rehybridization leads to significant improvement in repeatability (R.S.D.<6%, n=5) and sensitivity (DeltaF=34 Hz/1000 E. coli cells) as compared to existing manual method (R.S.D.=19%, n=5 and DeltaF=26 Hz/1000 E. coli cells, respectively). Down to 23 E. coli cells are detected, satisfying the HKEPD requirements for E. coli count in beach water.[Abstract] [Full Text] [Related] [New Search]