These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Noninvasive assessment of cardiac output using thoracic electrical bioimpedance in hemodynamically stable and unstable patients after cardiac surgery: a comparison with pulmonary artery thermodilution. Author: Suttner S, Schöllhorn T, Boldt J, Mayer J, Röhm KD, Lang K, Piper SN. Journal: Intensive Care Med; 2006 Dec; 32(12):2053-8. PubMed ID: 17039348. Abstract: OBJECTIVE: To compare noninvasive cardiac output (CO)measurement obtained with a new thoracic electrical bioimpedance (TEB) device, using a proprietary modification of the impedance equation, with invasive measurement obtained via pulmonary artery thermodilution. DESIGN: Prospective, observational study. SETTING: Surgical intensive care unit (ICU) of a university-affiliated community hospital. PATIENTS AND PARTICIPANTS: Seventy-four adult patients undergoing elective cardiac surgery with routine pulmonary artery catheter placement. INTERVENTIONS: None. MEASUREMENTS AND RESULTS: Simultaneous paired CO and cardiac index (CI) measurements by TEB and thermodilution were obtained in mechanically ventilated patients upon admission to the ICU. For analysis of CI data the patients were subdivided into a hemodynamically stable group and a hemodynamically unstable group. The groups were analyzed using linear regression and tests of bias and precision. We found a significant correlation between thermodilution and TEB (r = 0.83; n < 0.001), accompanied by a bias of -0.01 l/min/m(2) and a precision of +/-0.57 l/min/m(2) for all CI data pairs. Correlation, bias, and precision were not influenced by stratification of the data. The correlation coefficient, bias, and precision for CI were 0.86 (n< 0.001), 0.03 l/min/m(2), and +/-0.47 l/min/m(2) in hemodynamically stable patients and 0.79 (n< 0.001), 0.06 l/min/m(2), and +/-0.68 l/min/m(2) in hemodynamically unstable patients. CONCLUSIONS: Our results demonstrate a close correlation and clinically acceptable agreement and precision between CO measurements obtained with impedance cardiography using a new algorithm to calculate CO from variations in TEB, and those obtained with the clinical standard of care, pulmonary artery thermodilution, in hemodynamically stable and unstable patients after cardiac surgery.[Abstract] [Full Text] [Related] [New Search]