These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Slab optical waveguide high-acidity sensor based on an absorbance change of protoporphyrin IX. Author: Umemura T, Hotta H, Abe T, Takahashi Y, Takiguchi H, Uehara M, Odake T, Tsunoda K. Journal: Anal Chem; 2006 Nov 01; 78(21):7511-6. PubMed ID: 17073420. Abstract: A sensitive and fast-responsive evanescent wave absorption sensor has been constructed for pH measurements in highly acidic ranges. This sensor is based on a pH-dependent color change of protoporphyrin IX (PPIX). For the sensitive detection, a visible attenuated total reflection spectrometer with a slab optical waveguide (SOWG) was laboratory-made, and the guiding layer surface was modified with a PPIX-immobilized acrylamide-based thin membrane. The sensing membrane with a thickness of approximately 1 mum was directly fabricated on the SOWG glass surface by copolymerization of acrylamide, N,N'-methylene bisacrylamide, and PPIX in the narrow space confined by a cover plate. PPIX possesses two double bonds in its structure, and so it can be covalently incorporated into the membrane. The response characteristics of the PPIX-immobilized optode membrane were explored using aqueous solutions with different concentrations of HNO(3) or HCl. The optode membrane provided characteristic Soret band absorption spectra depending on the hydrogen ion concentration; the absorbance at 410 nm increased with increasing the concentrations in the range of 0.15-2 M, corresponding to the range of pH -0.3 to 0.8. The absorption signal reached 90% of its final value within 10 s, while the absorption signal was quite readily returned to background level simply by passing 2 mL of distilled water through a flow cell with a volume of 16.5 muL placed on the SOWG. Due to the rapid response and reversibility, this sensor could be operated in a flow-through mode as well as in a conventional static mode, where deionized water was conveniently used as a carrier and conditioning solution. In terms of the stability and precision, this sensor showed no significant change in response even after 100 assays and after being stored in a dry condition for over 6 months. Relative standard deviations for 10 replicate measurements were less than 1.8% in the linear range, and the detection limit calculated from 3 times of the standard deviation was 0.02 pH unit.[Abstract] [Full Text] [Related] [New Search]