These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: A simple fluorometric method for the determination of sulfur dioxide in ambient air with a passive sampler.
    Author: Chang W, Okamoto M, Korenaga T.
    Journal: Environ Sci; 2006; 13(5):257-62. PubMed ID: 17095999.
    Abstract:
    A simple and rapid fluorescence detection method was used for the determination of sulfur dioxide (SO(2)) in ambient air collected by a passive sampler. Gaseous SO(2) was absorbed as sulfite ions into an absorbing solution of triethanolamine (TEA) contained in an adsorbent sheet and reacted with N-(9-acridinyl)maleimide (NAM), which was used as a fluorescent reagent. TEA was also used as a buffer solution in this study. The calibration curve of SO(2) showed a linear correlation R(2)=0.992, and the relative standard deviation (RSD) was 2.4% for 50 ppb SO(2) with six repeated measurements. It was satisfactory to apply this method to determine the SO(2) level for simultaneous multipoint monitoring.
    [Abstract] [Full Text] [Related] [New Search]