These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Are placental chorionic capillary nucleated red blood cell counts useful compared to umbilical cord blood tests?
    Author: McCarthy JM, Gilbert-Barness E, Tsibris JC, Spellacy WN.
    Journal: Fetal Diagn Ther; 2007; 22(2):121-3. PubMed ID: 17135757.
    Abstract:
    OBJECTIVE: To compare measurement of fetal nucleated red blood cell (NRBC) counts in paired histologic samples of the placenta and umbilical cord bloods. METHOD: Forty-five randomly selected pregnancies had two determinations of the NRBC count. A sample of umbilical venous blood had a NRBC count measured and sections of the placenta were examined for their villous capillary NRBC counts. RESULTS: Umbilical venous blood had NRBC/100 white blood cell counts ranging from 0 to 67. Paired evaluation of placental tissue had NRBC counts of 0-5 with 60% being zero compared to 8% zero counts in cord blood. There was no correlation between the paired counts (R(2) = 0.04). CONCLUSION: Umbilical cord blood provides different information on fetal NRBC count than does histologic study of the placenta.
    [Abstract] [Full Text] [Related] [New Search]