Title: Creep behavior of commonly used suture materials in abdominal wall surgery. Author: Nout E, Lange JF, Salu NE, Wijsmuller AR, Hop WC, Goossens RH, Snijders CJ, Jeekel J, Kleinrensink GJ. Journal: J Surg Res; 2007 Mar; 138(1):51-5. PubMed ID: 17137599. Abstract: BACKGROUND: The incidence of incisional hernia after abdominal wall closure is high. Furthermore, recurrence is a significant complication after correction of all abdominal wall hernias. Besides surgeon- and patient-related factors, in this experimental study a third factor, i.e., creep behavior of suture materials, is introduced and evaluated. MATERIALS AND METHODS: Creep measurements were performed on 0 and 2-0 Prolene (Ethicon, Johnson & Johnson Intl., Somerville, NJ) and 1 and 2-0 PDSII (Ethicon, Johnson & Johnson Intl.) sutures. Two different loads were used representing normal intra-abdominal pressure (IAP) and pathological IAP. A mean percentage of elongation was calculated for each type of suture material. Statistical analysis was performed using analysis of variance. RESULTS: All suture materials showed significant (3-51%) creep behavior. Prolene sutures showed more creep than PDSII sutures in both loading conditions. CONCLUSIONS: As significant creep was demonstrated for commonly used suture materials, creep might be a significant influential factor with regard to the etiology of incisional hernias and recurrence after abdominal wall hernia repair.[Abstract] [Full Text] [Related] [New Search]