These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Midterm results of Metasul metal-on-metal total hip arthroplasty.
    Author: Saito S, Ryu J, Watanabe M, Ishii T, Saigo K.
    Journal: J Arthroplasty; 2006 Dec; 21(8):1105-10. PubMed ID: 17162168.
    Abstract:
    We assessed 106 total hip arthroplasties performed with a new metal-on-metal hip system; the patients were monitored for at least 5 years. The average Harris Hip Score of the patients was 39.5 points before surgery and 87.8 points at final follow-up evaluation. Radiographically, the acetabular component was stable in 103 hips and possibly unstable in 3 hips. The femoral component was bone ingrown in 97 hips and stable and fibrous in 9. After surgery, 6 hips dislocated. The polyethylene liner dissociated in one patient. No patient exhibited clear signs of loosening, migration, or osteolysis. Distal femoral cortical hypertrophy was seen in 35.8% of the cases. Survival at the mean follow-up point (6.4 years) was 99.1%. There was no significant difference in serum chromium concentration between metal-on-metal bearings and polyethylene-on-metal bearings (control subjects). This study found that metal-on-metal total hip arthroplasty produces excellent midterm results.
    [Abstract] [Full Text] [Related] [New Search]