These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Determinants of normal retinal nerve fiber layer thickness measured by Stratus OCT.
    Author: Budenz DL, Anderson DR, Varma R, Schuman J, Cantor L, Savell J, Greenfield DS, Patella VM, Quigley HA, Tielsch J.
    Journal: Ophthalmology; 2007 Jun; 114(6):1046-52. PubMed ID: 17210181.
    Abstract:
    PURPOSE: To determine the effects of age, optic disc area, ethnicity, eye, gender, and axial length on the retinal nerve fiber layer (RNFL) in the normal human eye as measured by Stratus OCT (optical coherence tomography). DESIGN: Cross-sectional observational study. PARTICIPANTS: Three hundred twenty-eight normal subjects 18 to 85 years old. METHODS: Peripapillary Fast RNFL scans performed by Stratus OCT with a nominal diameter of 3.46 mm centered on the optic disc were performed on one randomly selected eye of each subject. MAIN OUTCOME MEASURES: Linear regression analysis of the effects of age, ethnicity, gender, eye, axial length, and optic disc area on peripapillary RNFL thickness. RESULTS: The mean RNFL thickness for the entire population was 100.1 microm (standard deviation, 11.6). Thinner RNFL measurements were associated with older age (P<0.001); being Caucasian, versus being either Hispanic or Asian (P = 0.006); greater axial length (P<0.001); or smaller optic disc area (P = 0.010). For every decade of increased age, mean RNFL thickness measured thinner by approximately 2.0 microm (95% confidence interval [CI], 1.2-2.8). For every 1-mm-greater axial length, mean RNFL thickness measured thinner by approximately 2.2 microm (95% CI, 1.1-3.4). For every increase in square millimeter of optic disc area, mean RNFL thickness increased by approximately 3.3 microm (95% CI, 0.6-5.6). Comparisons between ethnic groups revealed that Caucasians had mean RNFL values (98.1+/-10.9 microm) slightly thinner than those of Hispanics (103.7+/-11.6 microm; P = 0.022) or Asians (105.8+/-9.2 microm; P = 0.043). There was no relationship between RNFL thickness and eye or gender. CONCLUSIONS: Retinal nerve fiber layer thickness, as measured by Stratus OCT, varies significantly with age, ethnicity, axial length, and optic disc area. These variables may need to be taken into account when evaluating patients for diagnosis and follow-up of glaucoma, particularly at the lower boundary of the normal range. Due to the relatively small numbers of subjects of Asian and African descent in the normative database, conclusions regarding the effect of ethnicity should be interpreted with caution.
    [Abstract] [Full Text] [Related] [New Search]