These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Delayed presentation of low molecular weight heparin treatment failure in a patient with mitral valve prosthesis. Author: Stamou SC, Lefrak EE. Journal: J Card Surg; 2007; 22(1):61-2. PubMed ID: 17239216. Abstract: We describe a patient who developed right basal ganglion stroke and partial obstruction of St. Jude mitral valve prosthesis as a result of treatment failure with enoxaparin. The patient did not develop the embolic complication from the thrombosis until almost 4 months after the bridging sequence with low molecular weight heparin. The patient underwent thrombectomy of the mitral valve. At least 16 similar cases with mechanical valve prostheses and treatment failure of low molecular weight heparin have been reported.[Abstract] [Full Text] [Related] [New Search]