These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Surface texture of four nanofilled and one hybrid composite after finishing.
    Author: Jung M, Sehr K, Klimek J.
    Journal: Oper Dent; 2007; 32(1):45-52. PubMed ID: 17288328.
    Abstract:
    This study evaluated the surface geometry of four nanocomposites and 1 hybrid composite after finishing with rigid rotary instruments. Four nanofilled composites (Premise, KerrHawe; Tetric EvoCeram, Ivoclar Vivadent; Filtek Supreme, 3M ESPE; Ceram X Duo, Dentsply) and one hybrid composite (Herculite XRV, KerrHawe) were used for the study. Sixty specimens were made of each product, 7 x 7 mm in size. Fifteen specimens of each composite were subjected to the following finishing procedures: a 30 microm diamond (FM 1), a sequence of a 30 microm and a 20 microm diamond (FM 2) and a 30 microm diamond followed by a 12-fluted tungsten carbide finishing bur (FM 3). As a reference, 15 other specimens of each material were treated with Sof-Lex discs. Evaluation of the surfaces was done with laser-stylus profilometry. Roughness parameters were average roughness (Ra) and profile-length ratio (LR). Statistical analysis of the data was performed by two-way and one-way ANOVA and post-hoc tests by Scheffé. Additional qualitative assessment of the finished composite surfaces was done by scanning electron microscopy (SEM) at a tension of 25 kV. The composite materials and the finishing methods had a significant effect on surface roughness (p < 0.001 for Ra and LR). There were significant interactions between the materials and the finishing methods (p < 0.001 for Ra and LR). Compared to Herculite XRV, three of the nanocomposites were significantly smoother after finishing, according to FM 1-3 and after application of the Sof-Lex discs. Ceram X Duo and Herculite XRV had similar surface roughness in terms of Ra and LR. Compared to a single 30 microm diamond and a sequence of two diamonds (FM 2), significantly lower roughness values on all composites were achieved by using a 30 microm diamond followed by a tungsten carbide instrument (p < 0.001 for Ra and LR). Ra- and LR-values after FM 3 were similar or, in some cases, even lower than surface roughness measured after application of Sof-Lex discs. Evaluation by SEM revealed that the use of a 30 microm diamond caused detrimental surface alteration on all types of composites. A remarkable number of porosities were detected on 1 of the nanofilled composites.
    [Abstract] [Full Text] [Related] [New Search]