These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Peripheral vascular disease: comparison of continuous MR angiography and conventional MR angiography--pilot study.
    Author: Vogt FM, Zenge MO, Ladd ME, Herborn CU, Brauck K, Luboldt W, Barkhausen J, Quick HH.
    Journal: Radiology; 2007 Apr; 243(1):229-38. PubMed ID: 17329687.
    Abstract:
    The aim of this study was to prospectively assess the accuracy of three-dimensional magnetic resonance (MR) angiography for evaluation of stenosis in the peripheral arterial system with a continuous moving table technique, with conventional MR angiography as reference. This study was approved by the local institutional review board; informed consent was obtained. Five healthy male volunteers (mean age, 27 years; range, 24-35 years) and four men and one woman (mean age, 63 years; range, 46-78 years) with peripheral arterial occlusive disease were examined. Images obtained with both techniques showed excellent concordance (Cohen kappa = 0.75). Images obtained with a conventional protocol had higher quality compared with those obtained with the continuous technique (mean, 1.07 +/- 0.25 [standard deviation] vs 1.58 +/- 0.6; P < .05); small vessels appeared sharper on them. For detection of significant stenosis and occlusion, accuracy, sensitivity, and specificity of the continuous technique were 92.8%, 100%, and 89.2%, respectively.
    [Abstract] [Full Text] [Related] [New Search]