Search MEDLINE/PubMed
Title: A sequential injection method for the fluorimetric determination of aluminum in drinking water using 8-hydroxy-7-(4-sulfo-1-naphthylazo)-5-quinoline sulfonic acid. Author: Al-Kindy SM, Al-Ghamari SS, Suliman FE. Journal: Spectrochim Acta A Mol Biomol Spectrosc; 2007 Dec 31; 68(5):1174-9. PubMed ID: 17337239. Abstract: A robust and simple sequential injection (SI) method for the assay of aluminum ions in drinking water is described. The method is based on the complex formation between aluminum and 8-hydroxy-7-(4-sulfo-1-naphthylazo)-5-quinoline sulfonic acid (HSNQ). The fluorescence of the complex is monitored at an emission wavelength of 492 nm with excitation at 357 nm. The HSNQ concentration, aspirated reagent and sample volumes were optimized simultaneously using 3(3) full factorial design. The optimum operating conditions are aspirated sample and reagent volumes of 90 and 70 microL, respectively, and HSNQ concentration of 20 microM. With these conditions linear calibration curves were obtained from 100 to 800 ppb. The detection limit was 4 ppb. The maximum relative standard deviation of the method was 1.43% (n=5). The method was successfully applied for the determination of aluminum in drinking water samples.[Abstract] [Full Text] [Related] [New Search]