These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Tiotropium and simplified detection of dynamic hyperinflation. Author: Gelb AF, Taylor CF, McClean PA, Shinar CM, Rodrigues MT, Gutierrez CA, Chapman KR, Zamel N. Journal: Chest; 2007 Mar; 131(3):690-695. PubMed ID: 17356081. Abstract: STUDY OBJECTIVE: To detect dynamic hyperinflation (DH) by evaluating reduction in inspiratory capacity (IC) during metronome-paced hyperventilation (MPH) in patients with moderate-to-severe COPD, studied before and after treatment with tiotropium. METHODS: IC and FEV(1) were measured before and immediately after MPH at two times resting the respiratory rate for 20 s in 60 COPD patients (28 men; mean age, 66 +/- 10 years [+/- SD]) before and after 30 days of treatment with tiotropium bromide, 18 mug. Patients were encouraged to maintain a constant tidal volume during MPH. RESULTS: At baseline, mean FEV(1) was 1.5 +/- 0.1 L (+/- SE) [57 +/- 1.6% of predicted], mean FVC was 2.6 +/- 0.1L (77 +/- 1.8% of predicted), and mean FEV(1)/FVC was 56 +/- 1%. After 180 mug of aerosolized albuterol sulfate, mean FEV(1) was 1.7 +/- 0.1 L (63 +/- 1.5% of predicted) [p < 0.001] and mean FEV(1)/FVC was 58 +/- 1%. Compared to baseline, after 30 days and 1.5 h after tiotropium there was an increase in IC of 0.18 +/- 0.04L (p < 0.0001); FEV(1) of 0.13 +/- 0.03 L (5.6 +/- 0.8% of predicted; p = 0.0002); FVC of 0.22 +/- 0.05 L (6.5 +/- 1.3% of predicted; p < 0.001); and decrease in end-expiratory lung volume (EELV)/total lung capacity (TLC) of - 3.1 +/- 0.6% (p = 0.0001); a decrease in end-inspiratory lung volume (EILV)/TLC of - 2.9 +/- 1.3% (p = 0.03); and no change in TLC (- 0.06 +/- 0.05 L). Results following MPH-induced DH at baseline and after 30 days of tiotropium were similar, with decreases in IC (- 0.35 +/- 0.03 L; p < 0.001); FEV(1) (- 0.05 +/- 0.04 L; p = 0.2); and FVC (- 0.22 +/- 0.03 L; p < 0.0001); no change in TLC; and increases in EELV/TLC (11.8 +/- 1.0% of predicted; p < 0.0001) and EILV/TLC (4.0 +/- 1.3% of predicted, p < 0.003). CONCLUSION: In patients with moderate-to-severe COPD, tiotropium did not reduce MPH-induced DH and reduction in IC, compared to baseline. However, because tiotropium induced bronchodilation and increased baseline IC, lower operational lung volumes may blunt the effect of MPH-induced DH. The noninvasive simplicity of MPH-induced DH provides a clinically useful screening surrogate to monitor changes in IC following treatment with tiotropium.[Abstract] [Full Text] [Related] [New Search]