These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Correlation between optical coherence tomography images and histology of pigskin. Author: Kuranov R, Sapozhnikova V, Prough D, Cicenaite I, Esenaliev R. Journal: Appl Opt; 2007 Apr 01; 46(10):1782-6. PubMed ID: 17356622. Abstract: Noninvasive imaging techniques such as optical coherence tomography (OCT) are being widely used for early diagnostics of a variety of pathologies. Traditional tissue preparation for histological evaluation alters the dimensions of histological images such that differences between the dimensions of histologic and OCT images can be as great as 2.5-fold. This discrepancy complicates quantitative interpretation of OCT images. Here we used a steel ring sewn to the pigskin to avoid tissue deformation due to excision and fixation and used a surgical suture as a fixed tissue marker. With these techniques, we achieved good correlation between OCT and histological images with differences of less than 10%. The resulting method significantly enhances the diagnostic capabilities of the OCT technique.[Abstract] [Full Text] [Related] [New Search]