These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Bovine hemoglobin (glutamer-250, Hemopure)-specific immunoglobulin G antibody cross-reacts with human hemoglobin but does not lyse red blood cells in vitro. Author: Hamilton RG, Kickler TS. Journal: Transfusion; 2007 Apr; 47(4):723-8. PubMed ID: 17381632. Abstract: BACKGROUND: Bovine hemoglobin (Hb)-based oxygen carrier (HbOC-201; Hb glutamer-250, Hemopure, Biopure Corp.) is a blood replacement and augmentation drug that increases oxygen-carrying capacity of circulating blood in patients with anemia and acute blood loss. The objective of this study was to assess the biologic significance (cross-reactivity, hemolysis) of humoral immune responses in humans receiving repetitive HbOC-201 administrations. STUDY DESIGN AND METHODS: Serum samples containing immunoglobulin G (IgG) anti-HbOC-201 (n = 146) or no antibody (n = 16) were collected from subjects receiving HbOC-201 in clinical studies. IgG anti-HbOC-201 levels were quantified and the extent of cross-reactivity to human hemoglobin (HuHb) was assessed in direct-binding and competitive-inhibition immunoassays. Serum samples containing the highest levels of IgG anti-HbOC-201 were studied in a complement-mediated hemolysis assay for their ability to lyse human red cells (RBCs). RESULTS: The IgG anti-HbOC-201 levels in the antibody-positive serum samples ranged from 0.7 to 86.8 mug per mL. Of the 146 IgG anti-HbOC-201-positive serum samples, 88.4 percent contained IgG antibodies whose binding to solid-phase HbOC-201 was competitively inhibited by incubation with soluble HuHb (11.6% [<20% inhibition]; 63% [20%-80% inhibition]; and 25.4% [>81% inhibition]). Direct-binding analysis to solid-phase HuHb confirmed that 74 percent contained IgG antibodies reactive with HuHb. Dichotomous competitive inhibition and direct-binding IgG anti-HuHb data correlated significantly (r(2) = 0.77, p < 0.001). Serum samples with the highest levels of IgG anti-HuHb, as identified from clinical studies, did not lyse human RBCs in the presence of exogenous complement or induce the direct sensitization of RBCs with human IgG or complement. CONCLUSION: These analyses indicate that HbOC-201 administration elicits IgG antibodies in humans that react with bovine and HuHb, but do not cause hemolysis in vitro.[Abstract] [Full Text] [Related] [New Search]