These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Development and application of immunoaffinity column chromatography for atrazine in complex sample media. Author: Chuang JC, Van Emon JM, Jones R, Durnford J, Lordo RA. Journal: Anal Chim Acta; 2007 Jan 30; 583(1):32-9. PubMed ID: 17386523. Abstract: A rabbit antibody immunoaffinity (IA) column procedure was evaluated as a cleanup method for the determination of atrazine in soil, sediment, and food. Four IA columns were prepared by immobilizing a polyclonal rabbit anti-atrazine antibody solution to HiTrap Sepharose columns. Atrazine was bound to the IA columns when the loading solvents were either 100% water, 2% acetonitrile in water, or 10% methanol in phosphate buffered saline (PBS). Quantitative removal of atrazine from the IA columns was achieved with elution solvents of either 70% ethanol in water, 70% methanol in water, or 100% methanol. One control column was prepared using nonspecific rabbit IgG antibody. This control column did not retain any applied atrazine indicating atrazine did not bind indiscriminately to protein or the Sepharose support. The four IA columns showed reproducible coupling efficiency for the immobilization of the atrazine antibody and consistent binding and releasing of atrazine. The coupling efficiency (4.25 mg of antibody in 1 mL of resin bed) for the four IA columns ranged from 93 to 97% with an average of 96+/-2% (2.1%). Recoveries of the 500, 50, and 5 ng mL(-1) atrazine standard solutions from the four IA columns were 107+/-7% (6.5%), 122+/-14% (12%), and 114+/-9% (8.0%) respectively, based on enzyme-linked immunosorbent assay (ELISA) data. The maximum loading was approximately 700 ng of atrazine for each IA column (approximately 0.16 microg of atrazine per mg of antibody). The IA columns could withstand 100% methanol as the elution solvent and could be reused more than 50 times with no change in performance. The IA columns were challenged with soil, sediment, and duplicate-diet food samples and effectively removed interferences from these various matrices for subsequent gas chromatography/mass spectrometry (GC/MS) or ELISA analysis. The log-transformed ELISA and GC/MS data were significantly correlated for soil, sediment and food samples although the ELISA values were slightly higher than those obtained by GC/MS. The IA column cleanup procedure coupled with ELISA analysis could be used as an alternative effective analytical method for the determination of atrazine in complex sample media such as soil, sediment, and food samples.[Abstract] [Full Text] [Related] [New Search]