These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Microtensile bond strength of photoactivated and autopolymerized adhesive systems to root dentin using translucent and opaque fiber-reinforced composite posts.
    Author: Mallmann A, Jacques LB, Valandro LF, Muench A.
    Journal: J Prosthet Dent; 2007 Mar; 97(3):165-72. PubMed ID: 17394915.
    Abstract:
    STATEMENT OF PROBLEM: The use of fiber-reinforced composite resin posts in endodontically treated teeth has increased. However, selecting an adhesive system that provides reliable and long-lasting bonding to root canal dentin remains difficult. PURPOSE: This study evaluated the microtensile bond strength of 2 adhesive systems to root dentin and 2 different fiber-reinforced composite resin posts. MATERIAL AND METHODS: Forty single-rooted teeth were instrumented, and root canals were prepared for translucent (Light Post [LP]) or opaque (Aestheti Post [AP]) quartz fiber-reinforced composite resin posts. Two adhesive systems were used: Scotchbond Multi-Purpose Plus (SBMP) (autopolymerized) as a control group, and Single Bond (SB) (photoactivated). Teeth were assigned to 4 groups (n=10): SBMP+LP, SBMP+AP, SB+LP, SB+AP. After post cementation, roots were perpendicularly sectioned into 1-mm-thick slices, which were trimmed to obtain dumbbell-shaped specimens. The specimens were divided into 3 regions: cervical (C), middle (M), and apical (A). To determine the bond strength, the bonding area of each specimen was calculated, and specimens were attached to a device to test microtensile strength at a crosshead speed of 1 mm/min. Data were analyzed using 3-way analysis of variance and the Tukey test (alpha=.05). Fractured specimens were examined under a x 25 stereomicroscope to determine the mode of fracture. RESULTS: There were significant differences only among root dentin regions (P<.001). The cervical third (9.16 +/- 1.18 MPa) presented higher mean bond strength values, especially for SBMP. Middle and apical regions demonstrated lower values (7.08 +/- 0.92 and 7.31 +/- 0.60 MPa, respectively). Adhesive and post main factors did not demonstrate significance. Also, no interaction was significant. No cohesive fractures within resin cement, fiber-reinforced composite resin post, or root dentin were identified. CONCLUSIONS: Both adhesive systems tested demonstrated reliable bonding when used with translucent and opaque fiber-reinforced composite posts.
    [Abstract] [Full Text] [Related] [New Search]