These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Frequency doubling perimetry and short-wavelength automated perimetry to detect early glaucoma. Author: Leeprechanon N, Giaconi JA, Manassakorn A, Hoffman D, Caprioli J. Journal: Ophthalmology; 2007 May; 114(5):931-7. PubMed ID: 17397926. Abstract: PURPOSE: To compare the ability of short-wavelength automated perimetry (SWAP) and frequency doubling perimetry (FDP) to detect early glaucoma damage. DESIGN: Prospective case-control study using a comparative case series. PARTICIPANTS: Forty-two patients with preperimetric glaucomatous optic nerve damage and a normal standard achromatic perimetry (SAP) in 1 eye, but with contralateral SAP abnormalities, and 35 normals. METHODS: Forty-two patients and 35 normals underwent SWAP and FDP (Humphrey 24-2; Carl Zeiss Meditec, Inc., Dublin, CA). Correlations of mean deviation (MD) and pattern standard deviation (PSD) of the 2 groups were calculated. The number of defects at P<0.05 and P<0.01 on total deviation (TD) and pattern deviation (PD) plots were compared. Diagnostic precision and agreement on location of abnormalities were determined. MAIN OUTCOME MEASURES: Correlations and comparisons of global indices between SWAP and FDP: MD, PSD, TD, and PD abnormal number of points. RESULTS: Significant correlations in the glaucoma group were found between SWAP and FDP for MD (r = 0.54; P<0.008) and PSD (r = 0.49; P<0.001). Defects on the TD and PD plots were detected more frequently by FDP in the glaucoma group, although they were significant only for PD at P<0.01 (P = 0.024). Areas under receiver operator characteristic curves for MD of SWAP and PSD of FDP were 0.74 and 0.67, respectively (P = 0.37). Using defined defect criteria, FDP had a significantly higher sensitivity (72% vs. 54%; P = 0.02) and similar specificity (53% vs. 44%; P = 0.12) compared with SWAP. Agreement on defect location was moderate (kappa, 0.46). Testing time for SWAP was longer than for FDP in both glaucomatous and normal eyes (P<0.001). CONCLUSIONS: Short-wavelength automated perimetry and FDP showed similar ability to detect visual dysfunction in patients with preperimetric glaucoma. Long-term follow-up is required to define their role in predicting subsequent SAP defects.[Abstract] [Full Text] [Related] [New Search]