These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Comparison of the sensitivities of seven N-nitrosamines in pre-screened waters using an automated preconcentration system and gas chromatography with different detectors.
    Author: Jurado-Sánchez B, Ballesteros E, Gallego M.
    Journal: J Chromatogr A; 2007 Jun 22; 1154(1-2):66-73. PubMed ID: 17442322.
    Abstract:
    A simple, expeditious procedure for confirming the presence of N-nitrosamines in previously screened positive water samples was proposed. Water samples were continuously aspirated into a photometric flow system for screening. Positive samples were then confirmed and N-nitrosamines were identified by gas chromatography using different detectors (mass spectrometry, flame ionization and nitrogen-phosphorus). The system for the screening purpose was based on the preconcentration of the analytes onto a sorbent column, elution, and derivatization to form nitrite, then formation of a coloured product (Griess reaction) and photometric detection. The detection limits of the gas chromatographic method for 100 ml of sample were 2.0-3.5 microg/l, 20-80 and 3-13 ng/l for flame ionization, nitrogen-phosphorus and mass spectrometric detectors, respectively. The precision as RSD was similar for all detectors (3.0-6.5%). The screening of different types of water showed that wastewaters contain levels of N-nitrosamines that can be detected only using MS as a detector.
    [Abstract] [Full Text] [Related] [New Search]