These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Exposure to airborne asbestos associated with simulated cable installation above a suspended ceiling.
    Author: Keyes DL, Chesson J, Ewing WM, Faas JC, Hatfield RL, Hays SM, Longo WE, Millette JR.
    Journal: Am Ind Hyg Assoc J; 1991 Nov; 52(11):479-84. PubMed ID: 1746410.
    Abstract:
    Installing cable above a suspended ceiling in the presence of asbestos-containing fireproofing is an example of an activity that may disturb in-place asbestos and associated dust and debris. Two simulations of cable installation were conducted in a room of an unoccupied school to test the extent of such disturbance and resulting elevations in airborne asbestos. Average airborne asbestos concentrations in the room increased over 500-fold during the simulations, with several samples exceeding 50 structures per cubic centimeter (s/cm3), as measured by transmission electron microscopy (TEM) with an indirect preparation technique. Elevated concentrations persisted during a subsequent cleaning of horizontal surfaces in the room and for several hours thereafter. Personal samples collected on the cable installers yielded TEM measurements averaging approximately 68 s/cm3 for the two simulations.
    [Abstract] [Full Text] [Related] [New Search]