These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Relationship between maximal oxygen uptake and oxygen uptake attained during treadmill middle-distance running. Author: James DV, Sandals LE, Draper SB, Wood DM. Journal: J Sports Sci; 2007 Jun; 25(8):851-8. PubMed ID: 17474038. Abstract: Traditionally, it has been assumed that during middle-distance running oxygen uptake (VO2) reaches its maximal value (VO2max) providing the event is of a sufficient duration; however, this assumption is largely based on observations in individuals with a relatively low VO2max. The aim of this study was to determine whether VO2max is related to the VO2 attained (i.e. VO2peak) during middle-distance running on a treadmill. Fifteen well-trained male runners (age 23.3 +/- 3.8 years, height 1.80 +/- 0.10 m, body mass 76.9 +/- 10.6 kg) volunteered to participate in the study. The participants undertook two 800-m trials to examine the reproducibility of the VO2 response. These two trials, together with a progressive test to determine VO2max, were completed in a randomized order. Oxygen uptake was determined throughout each test using 15-s Douglas bag collections. Following the application of a 30-s rolling average, the highest VO2 during the progressive test (i.e. VO2max) was compared with the highest VO2 during the 800-m trials (i.e. VO2peak) to examine the relationship between VO2max and the VO2 attained in the 800-m trials. For the 15 runners, VO2max was 58.9 +/- 7.1 ml x kg(-1) x min(-1). Two groups were formed using a median split based on VO2max. For the high and low VO2max groups, VO2max was 65.7 +/- 3.0 and 52.4 +/- 1.8 ml x kg(-1) x min(-1) respectively. The limits of agreement (95%) for test-retest reproducibility for the VO2 attained during the 800-m trials were +/- 3.5 ml x kg(-1) x min(-1) for a VO2peak of 50.6 ml x kg(-1) x min(-1) (the mean VO2peak for the low VO2max group) and +/- 2.3 ml x kg(-1) x min(-1) for a VO2peak of 59.0 ml x kg(-1) x min(-1) (the mean VO2peak for the high VO2max group), with a bias in VO2peak between the 800-m runs (i.e. the mean difference) of 1.2 ml x kg(-1) x min(-1). The VO2peak for the 800-m runs was 54.8 +/- 4.9 ml x kg(-1) x min(-1) for all 15 runners. For the high and low VO2max groups, VO2peak was 59.0 +/- 3.3 ml x kg(-1) x min(-1) (i.e. 90% VO2max) and 50.6 +/- 2.0 ml x kg(-1) x min(-1) (i.e. 97% VO2max) respectively. The negative relationship (-0.77) between VO2max and % VO2max attained for all 15 runners was significant (P = 0.001). These results demonstrate that (i) reproducibility is good and (ii) that VO2max is related to the %VO2max achieved, with participants with a higher VO2max achieving a lower %VO2max in an 800-m trial on a treadmill.[Abstract] [Full Text] [Related] [New Search]