  • Title: Enhanced electron transfer for hemoglobin entrapped in a cationic gemini surfactant films on electrode and the fabrication of nitric oxide biosensor.
    Author: Wang F, Chen X, Xu Y, Hu S, Gao Z.
    Journal: Biosens Bioelectron; 2007 Sep 30; 23(2):176-82. PubMed ID: 17482453.
    Abstract:
    The direct electrical communication between hemoglobin (Hb) and GCE surface was achieved based on the immobilization of Hb in a cationic gemini surfactant film and characterized by electrochemical techniques. The cyclic voltammograms showed that direct electron transfer between Hb and electrode surface was obviously promoted and then a novel unmediated nitric oxide (NO) biosensor was constructed in view of this protein-based electrode. This modified electrode showed an enzyme-like activity towards the reduction of NO and its amperometric response to NO was well-behaved with a rapid response time and displaying Michaelis-Menten kinetics with a calculated Km(app) value of 84.37 micromol L(-1). The detection limit was estimated to be 2.00 x 10(-8)mol L(-1). This biosensor was behaving as expected that it had a good stability and reproducibility, a higher sensitivity and selectivity and should has a potential application in monitoring NO released from biologic samples.